- Title
- Investigation of polarization mode dispersion measurement perfomance in optical fibre with a focus on the fixed analyzer technique
- Creator
- Gamatham, Romeo Reginald Gunther
- Subject
- Fiber optics
- Subject
- Polarization (Light)
- Date Issued
- 2008
- Date
- 2008
- Type
- Thesis
- Type
- Masters
- Type
- MSc
- Identifier
- vital:10524
- Identifier
- http://hdl.handle.net/10948/957
- Identifier
- Fiber optics
- Identifier
- Polarization (Light)
- Description
- The work presented in this dissertation is a comparative study of polarization mode dispersion (PMD) measurement performance where the fixed analyzer (FA) technique was built and tested for the first time in South Africa. Techniques involved in the study are: the Jones matrix eigenanalysis (JME), generalised interferometric technique (GINTY) and the FA technique, with a particular focus on the FA technique. The FA PMD measurement technique determines the average differential group delay (DGD) from the transmitted intensity spectrum through a polarizer and has three analysis methods (extrema counting, mean level crossing and Fourier analysis) which were all evaluated. PMD measurements were performed in the laboratory on several different fibre types and in the field on buried deployed Telkom fibre links (28.8 km). The techniques showed good agreement in the measured PMD value, both in the laboratory and field measurements. In particular very good agreement was found between the JME average DGD and the extrema counting analysis PMD value. The GINTY and FA Fourier analysis method also gave very similar PMD values. It was found that the fibre birefringence and the mode coupling manifest in different ways on the intensity spectrum. By using the FA ratio method, the length regimes of the different fibre types were determined. Three characteristics of the FA technique were investigated, namely: wavelength window variation, sampling and input SOP scrambling. It was found that the wavelength window and the PMD are inversely proportional. Correct sampling plays a significant role in determining the correct measured PMD value. Lastly an average PMD value over the PMD values for different input SOPs serves as a better representation of the true PMD value. An additional study showed that the FA technique and a developed Poincaré sphere analysis method agree very well regarding the PMD value.
- Format
- x, 149 leaves
- Format
- Publisher
- Nelson Mandela Metropolitan University
- Publisher
- Faculty of Science
- Language
- English
- Rights
- Nelson Mandela Metropolitan University
- Hits: 1173
- Visitors: 1253
- Downloads: 105
Thumbnail | File | Description | Size | Format | |||
---|---|---|---|---|---|---|---|
View Details Download | SOURCEPDF | 2 MB | Adobe Acrobat PDF | View Details Download |