A sensitive and reliable method for the detection of lipid peroxidation in biological tissues
- Anoopkumar-Dukie, Shailendra, Walker, Roderick B, Daya, Santylal
- Authors: Anoopkumar-Dukie, Shailendra , Walker, Roderick B , Daya, Santylal
- Date: 2001
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184325 , vital:44208 , xlink:href="https://doi.org/10.1211/0022357011775299"
- Description: A simple, accurate and cost effective method has been designed for the determination of lipid peroxidation in biological tissue samples. The method was a modification and improvement on existing methods available for lipid peroxidation determination. Solid-phase extraction was used to separate the thiobarbituric acid–malondialdehyde complex from thiobarbituric acidreactive substances and HPLC was performed using a C18 (Waters Spherisorb, 5 µm, 250¬4.6 mm i.d.) column to achieve isolation of the complex. The procedure was validated with respect to linearity of calibration (0.998), precision, sensitivity and limits of quantitation (1 nmol mL−1) and detection (0.5 nmol mL−1). Resorcinol was used as an external standard. The method was tested by inducing free radical generation with a known free radical generator, quinolinic acid, in rat brain homogenate. The results showed that the method presented allowed detection of lipid peroxidation products at concentrations in the nanomolar (nM) range compared with the micromolar (µM) range detected by other methods, thus rendering it suitable for use with biological samples. In addition, the modified method allowed for detection of the purified lipid peroxidation products, thus eliminating the possibility of simultaneous detection of impurities that absorb at the same wavelength.
- Full Text:
- Date Issued: 2001
- Authors: Anoopkumar-Dukie, Shailendra , Walker, Roderick B , Daya, Santylal
- Date: 2001
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184325 , vital:44208 , xlink:href="https://doi.org/10.1211/0022357011775299"
- Description: A simple, accurate and cost effective method has been designed for the determination of lipid peroxidation in biological tissue samples. The method was a modification and improvement on existing methods available for lipid peroxidation determination. Solid-phase extraction was used to separate the thiobarbituric acid–malondialdehyde complex from thiobarbituric acidreactive substances and HPLC was performed using a C18 (Waters Spherisorb, 5 µm, 250¬4.6 mm i.d.) column to achieve isolation of the complex. The procedure was validated with respect to linearity of calibration (0.998), precision, sensitivity and limits of quantitation (1 nmol mL−1) and detection (0.5 nmol mL−1). Resorcinol was used as an external standard. The method was tested by inducing free radical generation with a known free radical generator, quinolinic acid, in rat brain homogenate. The results showed that the method presented allowed detection of lipid peroxidation products at concentrations in the nanomolar (nM) range compared with the micromolar (µM) range detected by other methods, thus rendering it suitable for use with biological samples. In addition, the modified method allowed for detection of the purified lipid peroxidation products, thus eliminating the possibility of simultaneous detection of impurities that absorb at the same wavelength.
- Full Text:
- Date Issued: 2001
The effect of variations in pH and temperature on stability of melatonin in aqueous solution
- Daya, Santylal, Walker, Roderick B, Glass, Beverley D, Anoopkumar-Dukie, Shailendra
- Authors: Daya, Santylal , Walker, Roderick B , Glass, Beverley D , Anoopkumar-Dukie, Shailendra
- Date: 2001
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184314 , vital:44207 , xlink:href="https://doi.org/10.1034/j.1600-079x.2001.310209.x"
- Description: Melatonin (N-acetyl-5-methoxytryptamine) has a diverse range of functions, including the control of neuroendocrine events. A number of studies have shown that melatonin may be of potential benefit for the treatment of insomnia, as well as neurodegenerative disorders. At present, there are numerous dosage forms of melatonin, with the oral route of administration being most popular. Presently, there is little information on the stability of melatonin over a pH range. With the changes in pH in the gastro-intestinal tract, as well as in different experimental conditions, information on the stability of melatonin would be important. We used a high-performance liquid chromatography method to determine the stability of melatonin solutions over a pH range (1.2–12) at room temperature and at 37°C over a period of 21 days. The results show that no melatonin degradation occurred in the first 2 days. From days 3 to 21, there was a gradual decline in melatonin at all pHs, with the decline not exceeding 30%. No decline in melatonin levels occurred in the first 2 days at 37°C. From days 3 to 21, melatonin levels declined gradually, with the decline not exceeding 29%.
- Full Text:
- Date Issued: 2001
- Authors: Daya, Santylal , Walker, Roderick B , Glass, Beverley D , Anoopkumar-Dukie, Shailendra
- Date: 2001
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184314 , vital:44207 , xlink:href="https://doi.org/10.1034/j.1600-079x.2001.310209.x"
- Description: Melatonin (N-acetyl-5-methoxytryptamine) has a diverse range of functions, including the control of neuroendocrine events. A number of studies have shown that melatonin may be of potential benefit for the treatment of insomnia, as well as neurodegenerative disorders. At present, there are numerous dosage forms of melatonin, with the oral route of administration being most popular. Presently, there is little information on the stability of melatonin over a pH range. With the changes in pH in the gastro-intestinal tract, as well as in different experimental conditions, information on the stability of melatonin would be important. We used a high-performance liquid chromatography method to determine the stability of melatonin solutions over a pH range (1.2–12) at room temperature and at 37°C over a period of 21 days. The results show that no melatonin degradation occurred in the first 2 days. From days 3 to 21, there was a gradual decline in melatonin at all pHs, with the decline not exceeding 30%. No decline in melatonin levels occurred in the first 2 days at 37°C. From days 3 to 21, melatonin levels declined gradually, with the decline not exceeding 29%.
- Full Text:
- Date Issued: 2001
- «
- ‹
- 1
- ›
- »