A highly selective and sensitive pyridylazo-2-naphthol-poly (acrylic acid) functionalized electrospun nanofiber fluorescence “turn-off” chemosensory system for Ni 2+
- Adewuyi, Sheriff, Ondigo, Dezzline A, Zugle, Ruphino, Tshentu, Zenixole, Nyokong, Tebello, Torto, Nelson
- Authors: Adewuyi, Sheriff , Ondigo, Dezzline A , Zugle, Ruphino , Tshentu, Zenixole , Nyokong, Tebello , Torto, Nelson
- Date: 2012
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/246012 , vital:51428 , xlink:href="https://doi.org/10.1039/C2AY25182E"
- Description: A fluorescent nanofiber probe for the determination of Ni2+ was developed via the electrospinning of a covalently functionalized pyridylazo-2-naphthol-poly(acrylic acid) polymer. Fluorescent nanofibers with diameters in the range 230–800 nm were produced with uniformly dispersed fluorophores. The excitation and emission fluorescence were at wavelengths 479 and 557 nm respectively, thereby exhibiting a good Stokes' shift. This Ni2+ probe that employs fluorescence quenching in a solid receptor–fluorophore system exhibited a good correlation between the fluorescence intensity and nickel concentration up to 1.0 μg mL−1 based on the Stern–Volmer mechanism. The probe achieved a detection limit (3δ/S) of 0.07 ng mL−1 and a precision, calculated as a relative standard deviation (RSD) of more than 4% (n = 8). The concentration of Ni2+ in a certified reference material (SEP-3) was found to be 0.8986 μg mL−1, which is significantly comparable with the certified value of 0.8980 μg mL−1. The accuracy of the determinations, expressed as a relative error between the certified and the observed values of certified reference groundwater was ≤0.1%. The versatility of the nanofiber probe was demonstrated by affording simple, rapid and selective detection of Ni2+ in the presence of other competing metal ions by direct analysis, without employing any further sample handling steps.
- Full Text:
- Date Issued: 2012
- Authors: Adewuyi, Sheriff , Ondigo, Dezzline A , Zugle, Ruphino , Tshentu, Zenixole , Nyokong, Tebello , Torto, Nelson
- Date: 2012
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/246012 , vital:51428 , xlink:href="https://doi.org/10.1039/C2AY25182E"
- Description: A fluorescent nanofiber probe for the determination of Ni2+ was developed via the electrospinning of a covalently functionalized pyridylazo-2-naphthol-poly(acrylic acid) polymer. Fluorescent nanofibers with diameters in the range 230–800 nm were produced with uniformly dispersed fluorophores. The excitation and emission fluorescence were at wavelengths 479 and 557 nm respectively, thereby exhibiting a good Stokes' shift. This Ni2+ probe that employs fluorescence quenching in a solid receptor–fluorophore system exhibited a good correlation between the fluorescence intensity and nickel concentration up to 1.0 μg mL−1 based on the Stern–Volmer mechanism. The probe achieved a detection limit (3δ/S) of 0.07 ng mL−1 and a precision, calculated as a relative standard deviation (RSD) of more than 4% (n = 8). The concentration of Ni2+ in a certified reference material (SEP-3) was found to be 0.8986 μg mL−1, which is significantly comparable with the certified value of 0.8980 μg mL−1. The accuracy of the determinations, expressed as a relative error between the certified and the observed values of certified reference groundwater was ≤0.1%. The versatility of the nanofiber probe was demonstrated by affording simple, rapid and selective detection of Ni2+ in the presence of other competing metal ions by direct analysis, without employing any further sample handling steps.
- Full Text:
- Date Issued: 2012
An ion-imprinted polymer for the selective extraction of mercury(II) ions in aqueous media
- Batlokwa, Bareki Shima, Chimuka, Luke, Tshentu, Zenixole, Cukrowska, Ewa, Torto, Nelson
- Authors: Batlokwa, Bareki Shima , Chimuka, Luke , Tshentu, Zenixole , Cukrowska, Ewa , Torto, Nelson
- Date: 2012
- Language: English
- Type: Article
- Identifier: vital:6566 , http://hdl.handle.net/10962/d1004125
- Description: A double-imprinted polymer exhibiting high sensitivity for mercury(II) in aqueous solution is presented. Polymer particles imprinted with mercury(II) were synthesised by copolymerising the functional and cross-linking monomers, N’–[3– (Trimethoxysilyl)–propyl]diethylenetriamine (TPET) and tetraethylorthosilicate (TEOS). A double-imprinting procedure employing hexadecyltrimethylammonium bromide (CTAB), as a second template to improve the efficiency of the polymer, was adopted. The imprinted polymer was characterised by FTIR, scanning electron microscopy (SEM) and the average size determined by screen analysis using standard test sieves. Relative selective coefficients (k`) of the imprinted polymer evaluated from selective binding studies between Hg2+ and Cu2+ or Hg2+ and Cd2+ were 10 588 and 3 147, respectively. These values indicated highly-favoured Hg2+ extractions over the 2 competing ions. The results of spiked and real water samples showed high extraction efficiencies of Hg2+ ions, (over 84%) as evaluated from the detected unextracted Hg2+ ions by ICP-OES. The method exhibited a dynamic response concentration range for Hg2+ between 0.01 and 20 μg/mℓ, with a detection limit (LOD, 3σ) of 0.000036 μg/mℓ (36 ng/ℓ) that meets the monitoring requirements for the USA EPA of 2 000 ng/ℓ for Hg2+ in drinking water. Generally, the data (n=10) had percentage relative standard deviations (%RSD) of less than 4%. Satisfactory results were also obtained when the prepared sorbent was applied for the pre-concentration of Hg2+ from an aqueous certified reference material. These findings indicate that the double-imprinted polymer has potential to be used as an efficient extraction material for the selective pre–concentration of mercury(II) ions in aqueous environments.
- Full Text:
- Date Issued: 2012
- Authors: Batlokwa, Bareki Shima , Chimuka, Luke , Tshentu, Zenixole , Cukrowska, Ewa , Torto, Nelson
- Date: 2012
- Language: English
- Type: Article
- Identifier: vital:6566 , http://hdl.handle.net/10962/d1004125
- Description: A double-imprinted polymer exhibiting high sensitivity for mercury(II) in aqueous solution is presented. Polymer particles imprinted with mercury(II) were synthesised by copolymerising the functional and cross-linking monomers, N’–[3– (Trimethoxysilyl)–propyl]diethylenetriamine (TPET) and tetraethylorthosilicate (TEOS). A double-imprinting procedure employing hexadecyltrimethylammonium bromide (CTAB), as a second template to improve the efficiency of the polymer, was adopted. The imprinted polymer was characterised by FTIR, scanning electron microscopy (SEM) and the average size determined by screen analysis using standard test sieves. Relative selective coefficients (k`) of the imprinted polymer evaluated from selective binding studies between Hg2+ and Cu2+ or Hg2+ and Cd2+ were 10 588 and 3 147, respectively. These values indicated highly-favoured Hg2+ extractions over the 2 competing ions. The results of spiked and real water samples showed high extraction efficiencies of Hg2+ ions, (over 84%) as evaluated from the detected unextracted Hg2+ ions by ICP-OES. The method exhibited a dynamic response concentration range for Hg2+ between 0.01 and 20 μg/mℓ, with a detection limit (LOD, 3σ) of 0.000036 μg/mℓ (36 ng/ℓ) that meets the monitoring requirements for the USA EPA of 2 000 ng/ℓ for Hg2+ in drinking water. Generally, the data (n=10) had percentage relative standard deviations (%RSD) of less than 4%. Satisfactory results were also obtained when the prepared sorbent was applied for the pre-concentration of Hg2+ from an aqueous certified reference material. These findings indicate that the double-imprinted polymer has potential to be used as an efficient extraction material for the selective pre–concentration of mercury(II) ions in aqueous environments.
- Full Text:
- Date Issued: 2012
- «
- ‹
- 1
- ›
- »