Amoxicillin removal from aqueous media using multi-walled carbon nanotubes
- Mohammadi, Ali, Kazemipour, Maryam, Walker, Roderick B, Ansari, Mehdi
- Authors: Mohammadi, Ali , Kazemipour, Maryam , Walker, Roderick B , Ansari, Mehdi
- Date: 2015
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/183861 , vital:44076 , xlink:href="https://doi.org/10.1080/1536383X.2013.866944"
- Description: Multi-walled carbon nanotubes (MWCNT) were used to separate amoxicillin from aqueous media. The parameters affecting amoxicillin adsorption such as pH, temperature, time, interferences of similar molecules, and the amount of adsorbent used were studied. Amoxicillin adsorption using MWCNT was compared to that using Fullerene C60 and activated carbon (AC). The adsorption efficiency of 0.1 and 0.2 g of MWCNT using in a continuous mode were 86.5% and 87.9%, respectively. Evaluation of the adsorbent capacity showed that each gram of MWCNT can absorb 22.9 mg amoxicillin. The effect of pH was studied over the range 2–8 and revealed that adsorption of the amoxicillin at the initial pH of 4.6 was more effective than any other pH. The adsorption of amoxicillin on MWCNT was much greater than Fullerene C60 and AC. Adsorption data showed that they were best fitted to the Langmuir isotherm.
- Full Text:
- Date Issued: 2015
- Authors: Mohammadi, Ali , Kazemipour, Maryam , Walker, Roderick B , Ansari, Mehdi
- Date: 2015
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/183861 , vital:44076 , xlink:href="https://doi.org/10.1080/1536383X.2013.866944"
- Description: Multi-walled carbon nanotubes (MWCNT) were used to separate amoxicillin from aqueous media. The parameters affecting amoxicillin adsorption such as pH, temperature, time, interferences of similar molecules, and the amount of adsorbent used were studied. Amoxicillin adsorption using MWCNT was compared to that using Fullerene C60 and activated carbon (AC). The adsorption efficiency of 0.1 and 0.2 g of MWCNT using in a continuous mode were 86.5% and 87.9%, respectively. Evaluation of the adsorbent capacity showed that each gram of MWCNT can absorb 22.9 mg amoxicillin. The effect of pH was studied over the range 2–8 and revealed that adsorption of the amoxicillin at the initial pH of 4.6 was more effective than any other pH. The adsorption of amoxicillin on MWCNT was much greater than Fullerene C60 and AC. Adsorption data showed that they were best fitted to the Langmuir isotherm.
- Full Text:
- Date Issued: 2015
Electropolymerized Fluorinated Aniline-Based Fiber for Headspace Solid-Phase Microextraction and Gas Chromatographic Determination of Benzaldehyde in Injectable Pharmaceutical Formulations
- Mohammadi, Ali, Mohammadi, Somayeh, Moghaddam, Bayandori A, Masoumi, Vahideh, Walker, Roderick B
- Authors: Mohammadi, Ali , Mohammadi, Somayeh , Moghaddam, Bayandori A , Masoumi, Vahideh , Walker, Roderick B
- Date: 2014
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184120 , vital:44175 , xlink:href="https://doi.org/10.1093/chromsci/bmt152"
- Description: In this study, a simple method was developed and validated to detect trace levels of benzaldehyde in injectable pharmaceutical formulations by solid-phase microextraction coupled with gas chromatography–flame ionization detector. Polyaniline was electrodeposited on a platinum wire in trifluoroacetic acid solvent by cyclic voltammetry technique. This fiber shows high thermal and mechanical stability and high performance in extraction of benzaldehyde. Extraction and desorption time and temperature, salt effect and gas chromatography parameters were optimized as key parameters. At the optimum conditions, the fiber shows good linearity between peak area ratio of benzaldehyde/3-chlorobenzaldehyde and benzaldehyde concentration in the range of 50–800 ng/mL with percent relative standard deviation values ranging from 0.75 to 8.64% (n 5 3). The limits of quantitation and detection were 50 and 16 ng/mL, respectively. The method has the requisite selectivity, sensitivity, accuracy and precision to assay benzaldehyde in injectable pharmaceutical dosage forms.
- Full Text:
- Date Issued: 2014
- Authors: Mohammadi, Ali , Mohammadi, Somayeh , Moghaddam, Bayandori A , Masoumi, Vahideh , Walker, Roderick B
- Date: 2014
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184120 , vital:44175 , xlink:href="https://doi.org/10.1093/chromsci/bmt152"
- Description: In this study, a simple method was developed and validated to detect trace levels of benzaldehyde in injectable pharmaceutical formulations by solid-phase microextraction coupled with gas chromatography–flame ionization detector. Polyaniline was electrodeposited on a platinum wire in trifluoroacetic acid solvent by cyclic voltammetry technique. This fiber shows high thermal and mechanical stability and high performance in extraction of benzaldehyde. Extraction and desorption time and temperature, salt effect and gas chromatography parameters were optimized as key parameters. At the optimum conditions, the fiber shows good linearity between peak area ratio of benzaldehyde/3-chlorobenzaldehyde and benzaldehyde concentration in the range of 50–800 ng/mL with percent relative standard deviation values ranging from 0.75 to 8.64% (n 5 3). The limits of quantitation and detection were 50 and 16 ng/mL, respectively. The method has the requisite selectivity, sensitivity, accuracy and precision to assay benzaldehyde in injectable pharmaceutical dosage forms.
- Full Text:
- Date Issued: 2014
Electro‐oxidation of acetaminophen on nickel/poly (o‐aminophenol)/multi‐walled carbon nanotube nanocomposite modified graphite electrode.
- Naeemy, Ali, Mohammadi, Ali, Bakhtiari, Hediech, Ashouri, Nasim, Walker, Roderick B
- Authors: Naeemy, Ali , Mohammadi, Ali , Bakhtiari, Hediech , Ashouri, Nasim , Walker, Roderick B
- Date: 2014
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184107 , vital:44173 , xlink:href="https://ietresearch.onlinelibrary.wiley.com/doi/pdf/10.1049/mnl.2014.0197"
- Description: Poly(o-aminophenol) (POAP)/multi-walled carbon nanotube (MWCNT) nanocomposite and POAP in the absence of the MWCNT were fabricated by consecutive cyclic voltammetry (CV) on a graphite (G) electrode. The dispersion of nickel (II) ions was accomplished and incorporated into the polymeric electrodes (G/POAP and G/POAP-MWCNT) by immersing them into a 0.1 M nickel (II) solution. Following preparation of G/POAP/Ni and G/POAP-MWCNT/Ni, the electrochemical behaviour was examined using CV. Scanning electron microscopy was used for characterisation of the nanocomposite. The prepared electrodes showed enhanced electrocatalytic activity for the oxidation of acetaminophen and facilitated the detection of acetaminophen in a 0.1 M NaOH solution. Compared with the G/POAP/Ni electrode, the G/POAP-MWCNT/Ni electrode had a significant current response of acetaminophen oxidation because of the synergistic effects of POAP and the MWCNT. By CV, the calibration plot was linear in the range of 1–13 mM with standard deviation between 0.3 and 6.54% for acetaminophen. The G/POAP-MWCNT/Ni was successfully applied for acetaminophen determination in tablets and the results showed sufficient precision and achieved a mean recovery of 96.8% (R.S.D. = 4.9%).
- Full Text:
- Date Issued: 2014
- Authors: Naeemy, Ali , Mohammadi, Ali , Bakhtiari, Hediech , Ashouri, Nasim , Walker, Roderick B
- Date: 2014
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184107 , vital:44173 , xlink:href="https://ietresearch.onlinelibrary.wiley.com/doi/pdf/10.1049/mnl.2014.0197"
- Description: Poly(o-aminophenol) (POAP)/multi-walled carbon nanotube (MWCNT) nanocomposite and POAP in the absence of the MWCNT were fabricated by consecutive cyclic voltammetry (CV) on a graphite (G) electrode. The dispersion of nickel (II) ions was accomplished and incorporated into the polymeric electrodes (G/POAP and G/POAP-MWCNT) by immersing them into a 0.1 M nickel (II) solution. Following preparation of G/POAP/Ni and G/POAP-MWCNT/Ni, the electrochemical behaviour was examined using CV. Scanning electron microscopy was used for characterisation of the nanocomposite. The prepared electrodes showed enhanced electrocatalytic activity for the oxidation of acetaminophen and facilitated the detection of acetaminophen in a 0.1 M NaOH solution. Compared with the G/POAP/Ni electrode, the G/POAP-MWCNT/Ni electrode had a significant current response of acetaminophen oxidation because of the synergistic effects of POAP and the MWCNT. By CV, the calibration plot was linear in the range of 1–13 mM with standard deviation between 0.3 and 6.54% for acetaminophen. The G/POAP-MWCNT/Ni was successfully applied for acetaminophen determination in tablets and the results showed sufficient precision and achieved a mean recovery of 96.8% (R.S.D. = 4.9%).
- Full Text:
- Date Issued: 2014
Development and validation of a stability-indicating method for the quantitation of paclitaxel in pharmaceutical dosage forms
- Mohammadi, Ali, Esimaeili, Farnaz, Dinarvand, Rasoul, Atyabi, Fatemeh, Walker, Roderick B
- Authors: Mohammadi, Ali , Esimaeili, Farnaz , Dinarvand, Rasoul , Atyabi, Fatemeh , Walker, Roderick B
- Date: 2009
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184278 , vital:44196 , xlink:href="https://doi.org/10.1093/chromsci/47.7.599"
- Description: A simple, rapid stability-indicating isocratic assay has been developed and validated for the determination of Paclitaxel (PTX) in commercial injection formulations. The assay is performed using a Nucleosil RP-18 (5 µm, 250 × 4.0 mm i.d) column protected by a Nucleosil C18 precolumn (5 µm, 4.0 × 4.0 mm i.d.) with a mobile phase of methanol–water (80:20) and UV detection at 230 nm. The method was found to be specific for PTX in the presence of degradation products with an overall analytical run time of ~ 9 min. Accuracy reported as % bias was found to be 0.1–2.5% bias for all samples tested. Intra-assay precision (repeatability) was found to be 0.22–2.65% RSD, while inter-day precision (intermediate precision) was found to be 1.0–3.0% RSD for the samples studied. The calibration curve was found to be linear with the equation y = 29.78x + 7.65, and a linear regression coefficient of 0.9994 over the concentration range 0.05–20 µg/mL. The limits of quantitation and detection were 0.05 and 0.02 µg/mL, respectively. Taxol (30 mg/5 mL), a commercially available dosage form of PTX, was assayed and 100.6–103.6% of the label claim was recovered.
- Full Text:
- Date Issued: 2009
- Authors: Mohammadi, Ali , Esimaeili, Farnaz , Dinarvand, Rasoul , Atyabi, Fatemeh , Walker, Roderick B
- Date: 2009
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/184278 , vital:44196 , xlink:href="https://doi.org/10.1093/chromsci/47.7.599"
- Description: A simple, rapid stability-indicating isocratic assay has been developed and validated for the determination of Paclitaxel (PTX) in commercial injection formulations. The assay is performed using a Nucleosil RP-18 (5 µm, 250 × 4.0 mm i.d) column protected by a Nucleosil C18 precolumn (5 µm, 4.0 × 4.0 mm i.d.) with a mobile phase of methanol–water (80:20) and UV detection at 230 nm. The method was found to be specific for PTX in the presence of degradation products with an overall analytical run time of ~ 9 min. Accuracy reported as % bias was found to be 0.1–2.5% bias for all samples tested. Intra-assay precision (repeatability) was found to be 0.22–2.65% RSD, while inter-day precision (intermediate precision) was found to be 1.0–3.0% RSD for the samples studied. The calibration curve was found to be linear with the equation y = 29.78x + 7.65, and a linear regression coefficient of 0.9994 over the concentration range 0.05–20 µg/mL. The limits of quantitation and detection were 0.05 and 0.02 µg/mL, respectively. Taxol (30 mg/5 mL), a commercially available dosage form of PTX, was assayed and 100.6–103.6% of the label claim was recovered.
- Full Text:
- Date Issued: 2009
- «
- ‹
- 1
- ›
- »