Assessment of the prevalence of faecal coliforms and Escherichia coli o157:h7 in the final effluents of two wastewater treatment plants in Amahlathi Local Municipality of Eastern Cape Province, South Africa
- Authors: Ajibade, Adefisoye Martins
- Date: 2014
- Subjects: Sewage disposal plants , Escherichia coli -- South Africa -- Eastern Cape , Escherichia coli O157:H7 , Escherichia coli , Effluent quality -- Testing , Whole effluent toxicity testing , Water -- Purification
- Language: English
- Type: Thesis , Masters , MSc (Microbiology)
- Identifier: vital:11283 , http://hdl.handle.net/10353/d1016166 , Sewage disposal plants , Escherichia coli -- South Africa -- Eastern Cape , Escherichia coli O157:H7 , Escherichia coli , Effluent quality -- Testing , Whole effluent toxicity testing , Water -- Purification
- Description: The production of final effluents that meet discharged requirements and guidelines remain a major challenge particularly in the developing world with the resultant problem of surface water pollution. This study assessed the physicochemical and microbiological qualities of two wastewater treatment works in the Eastern Cape Province of South Africa in terms of the prevalence of faecal coliforms and Escherichia coli O157:H7 over a five month period. All physicochemical and microbiological analyses were carried out using standard methods. Data were collected in triplicates and analysed statistically using IBM SPSS version 20.0. The ranges of some of the physicochemical parameters that complied with set guidelines include pH (6.7 – 7.6), TDS (107 – 171 mg/L), EC (168 – 266 μS/cm), Temperature (15 – 24oC), NO3- (0 – 8.2 mg/L), NO2- (0.14 – 0.71 mg/L) and PO4 (1.05 – 4.50 mg/L). Others including Turbidity (2.64 – 58.00 NTU), Free Cl (0.13 – 0.65 mg/L), DO (2.20 – 8.48 mg/L), BOD (0.13 – 6.85 mg/L) and COD (40 – 482 mg/L) did not comply with set guidelines. The microbiological parameters ranged 0 – 2.7 × 104 CFU/100 ml for FC and 0 – 9.3 × 103 for EHEC CFU/100 ml, an indication of non-compliance with set guidelines. Preliminary identification of 40 randomly selected presumptive enterohemorrhagic E. coli isolates by Gram’s staining and oxidase test shows 100% (all 40 selected isolates) to be Gram positive while 90% (36 randomly selected isolates) were oxidase negative. Statistical correlation between the physicochemical and the microbiological parameters were generally weak except in the case of free chlorine and DO where they showed inverse correlation with the microbiological parameters. The recovery of EHEC showed the inefficiency of the treatment processes to effectively inactivate the bacteria, and possibly other pathogenic bacteria that may be present in the treated wastewater. The assessment suggested the need for proper monitoring and a review of the treatment procedures used at these treatment works.
- Full Text:
- Date Issued: 2014
Assessment of the prevalence of virulent Eschericia coli strains in the final effluents of wastewater treatment plants in the Eastern Cape Province of South Africa
- Authors: Osode, Augustina Nwabuje
- Date: 2010
- Subjects: Escherichia coli , Escherichia coli -- Genetics , Effluent quality -- Testing , Water -- Purification , Sewage disposal plants , Escherichia coli -- South Africa -- Eastern Cape , Whole effluent toxicity testing
- Language: English
- Type: Thesis , Doctoral , PhD (Microbiology)
- Identifier: vital:11246 , http://hdl.handle.net/10353/d1001062 , Escherichia coli , Escherichia coli -- Genetics , Effluent quality -- Testing , Water -- Purification , Sewage disposal plants , Escherichia coli -- South Africa -- Eastern Cape , Whole effluent toxicity testing
- Description: Escherichia coli (E. coli) is a common inhabitant of surface waters in the developed and developing worlds. The majority of E. coli cells present in water are not particularly pathogenic to humans; however, there are some present in small proportion that possess virulence genes that allow them to colonize the digestive tract. Pathogenic E. coli causes acute and chronic diarrheal diseases, especially among children in developing countries and in travelers in these locales. The present study, conducted between August 2007 and July 2008, investigated the prevalence and distribution of virulent E. coli strains as either free or attached cells in the final effluents of three wastewater treatment plants located in the Eastern Cape Province of South Africa and its impact on the physico-chemical quality of the receiving water body. The wastewater treatment plants are located in urban (East Bank Reclamation Works, East London), peri-urban (Dimbaza Sewage Treatment Works) and in rural area (Alice Sewage Treatment Works). The effluent quality of the treatment plants were acceptable with respect to pH (6.9-7.8), temperature (13.8-22.0 °C), dissolved oxygen (DO) (4.9-7.8 mg/L), salinity (0.12-0.17 psu), total dissolved solids (TDS) (119-162 mg/ L) and nitrite concentration (0.1-0.4 mg/l). The other xii physicochemical parameters that did not comply with regulated standards include the following: phosphate (0.1-4.0 mg/L); chemical oxygen demand (COD) (5-211 mg/L); electrical conductivity (EC) (237-325 μS/cm) and Turbidity (7.7-62.7 NTU). Results suggest that eutrophication is intensified in the vicinity of the effluent discharge points, where phosphate and nitrate were found in high concentrations. Presumptive E. coli was isolated from the effluent samples by culture-based methods and confirmed using Polymerase Chain Reaction (PCR) techniques. Antibiogram assay was also carried out using standard in vitro methods on Mueller Hinton agar. The viable counts of presumptive E. coli for the effluent samples associated with 180 μm plankton size ranged between 0 – 4.30 × 101 cfu/ml in Dimbaza, 0 – 3.88 × 101 cfu/ml in Alice and 0 – 8.00 × 101 cfu/ml in East London. In the 60 μm plankton size category E. coli densities ranged between 0 and 4.2 × 101 cfu/ml in Dimbaza, 0 and 2.13 × 101 cfu/ml in Alice and 0 and 8.75 × 101 cfu/ml in East London. Whereas in the 20 μm plankton size category presumptive E. coli density varied from 0 to 5.0 × 101 cfu/ml in Dimbaza, 0 to 3.75 × 101 cfu/ml in Alice and 0 to 9.0 × 101 cfu/ml in East London. The free-living presumptive E. coli density ranged between 0 and 3.13 × 101 cfu/ml in Dimbaza, between 0 and 8.0 × 101 cfu/ml in Alice and between 0 and 9.5 × 101 cfu/ml in East London. Molecular analysis successfully amplified target genes (fliCH7, rfbEO157, ial and aap) which are characteristic of pathogenic E. coli strains. The PCR assays using uidA-specific primer confirmed that a genetic region homologous in size to the E. coli uidA structural gene, including the regulatory region, was present in 3 of the E. coli isolates from Alice, 10 from Dimbaza and 8 from East London. Of the 3 E. coli isolates from Alice, 1 (33.3%) was positive for the fliCH7 genes and 3 was positive for rfbEO157 genes. Out of the 10 isolates from Dimbaza, 4 were xiii positive for fliCH7 genes, 6 were positive for the rfbEO157 genes and 1 was positive for the aap genes; and of the 8 isolates from East London, 1 was positive for fliCH7 genes, 2 were for the rfbEO157 genes, 6 were positive for the ial genes. Antimicrobial susceptibility profile revealed that all of the E. coli strains isolated from the effluent water samples were resistant (R) to linezolid, polymyxin B, penicillin G and sulfamethoxazole. The E. coli isolates from Dimbaza (9/10) and East London (8/8) respectively were resistant to erythromycin. All the isolates were found to be susceptible (S) to amikacin, ceftazidime, ciprofloxacin, colistin sulphate, ceftriaxone, cefotaxime, cefuroxime, ertapenem, gatifloxacin, gentamycin, imidazole, kanamycin, meropenem, moxifloxacin, neomycin, netilmicin, norfloxacin and tobramycin. The findings of this study revealed that the Alice wastewater treatment plant was the most efficient as it produced the final effluent with the least pathogenic E. coli followed by the Dimbaza wastewater treatment plant. In addition, the findings showed that the wastewater treatment plant effluents are a veritable source of pathogenic E. coli in the Eastern Cape Province watershed. We suggest that to maximize public health protection, treated wastewater effluent quality should be diligently monitored pursuant to ensuring high quality of final effluents.
- Full Text:
- Date Issued: 2010