Co phthalocyanine mediated electrochemical detection of the HER2 in the presence of Au and CeO2 nanoparticles and graphene quantum dots
- Centane, Sixolile, Nyokong, Tebello
- Authors: Centane, Sixolile , Nyokong, Tebello
- Date: 2023
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/360372 , vital:65083 , xlink:href="https://doi.org/10.1016/j.bioelechem.2022.108301"
- Description: In this work, cobalt tetra phenoxy acetic acid phthalocyanine (CoTAPc) is investigated as an electron mediator, immobilization platform for an HB5 aptamer and to enhance the electrochemical signal for the detection of human epidermal growth factor receptor 2 (HER2). Furthermore, the CoTAPc was combined individually with sulphur/nitrogen doped graphene quantum dots (SNGQDs), gold nanoparticles (AuNPs) and cerium oxide nanoparticles (CeO2NPs), on a glassy carbon electrode (GCE) via sequential adsorption. The CoTAPc and SNGQDs were also π-π stacked, used for electrode modification similarly to the rest of the other surfaces and applied towards the electrochemical detection of HER2. The designed sensors were characterized using electrochemical impedance spectroscopy (EIS). The designed aptasensors showed detection limits as low as 6.0 pg/mL. The real life applicability of the designed aptasensors was tested in human serum samples. The aptasensors showed great storage stability, sensitivity and specificity towards HER2, implying great potential for applications in early diagnosis of breast cancer.
- Full Text:
- Date Issued: 2023
- Authors: Centane, Sixolile , Nyokong, Tebello
- Date: 2023
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/360372 , vital:65083 , xlink:href="https://doi.org/10.1016/j.bioelechem.2022.108301"
- Description: In this work, cobalt tetra phenoxy acetic acid phthalocyanine (CoTAPc) is investigated as an electron mediator, immobilization platform for an HB5 aptamer and to enhance the electrochemical signal for the detection of human epidermal growth factor receptor 2 (HER2). Furthermore, the CoTAPc was combined individually with sulphur/nitrogen doped graphene quantum dots (SNGQDs), gold nanoparticles (AuNPs) and cerium oxide nanoparticles (CeO2NPs), on a glassy carbon electrode (GCE) via sequential adsorption. The CoTAPc and SNGQDs were also π-π stacked, used for electrode modification similarly to the rest of the other surfaces and applied towards the electrochemical detection of HER2. The designed sensors were characterized using electrochemical impedance spectroscopy (EIS). The designed aptasensors showed detection limits as low as 6.0 pg/mL. The real life applicability of the designed aptasensors was tested in human serum samples. The aptasensors showed great storage stability, sensitivity and specificity towards HER2, implying great potential for applications in early diagnosis of breast cancer.
- Full Text:
- Date Issued: 2023
Aptamer versus antibody as probes for the impedimetric biosensor for human epidermal growth factor receptor
- Centane, Sixolile, Nyokong, Tebello
- Authors: Centane, Sixolile , Nyokong, Tebello
- Date: 2022
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/229884 , vital:49720 , xlink:href="https://doi.org/10.1016/j.jinorgbio.2022.111764"
- Description: In the present work, the performance of aptamer and antibody bioreceptors for the detection of the human epidermal growth factor receptor (HER2) cancer biomarker on a glassy carbon electrode is reported. The carboxylic acid group rich graphene quantum dots (GQDs) modified with gold nanoparticles and a porphyrin binuclear framework (CoP-BNF) were used to modify the glassy carbon electrode. The aptamer and antibody were both amine functionalized and attached to GQDs and CoP-BNF through an amide bond. The designed immunosensors and aptasensors in this work were characterized using electrochemical impedance spectroscopy. The aptasensors, compared to the immunosensors gave better limit of detection values. The aptasensor outperforms the immunosensor in terms of its reusability and storability, while the immunosensor could not be regenerated for subsequent experiments. The potential applicability of all sensors in this work was also investigated, by detection of HER2 in spiked human serum with acceptable results.
- Full Text:
- Date Issued: 2022
- Authors: Centane, Sixolile , Nyokong, Tebello
- Date: 2022
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/229884 , vital:49720 , xlink:href="https://doi.org/10.1016/j.jinorgbio.2022.111764"
- Description: In the present work, the performance of aptamer and antibody bioreceptors for the detection of the human epidermal growth factor receptor (HER2) cancer biomarker on a glassy carbon electrode is reported. The carboxylic acid group rich graphene quantum dots (GQDs) modified with gold nanoparticles and a porphyrin binuclear framework (CoP-BNF) were used to modify the glassy carbon electrode. The aptamer and antibody were both amine functionalized and attached to GQDs and CoP-BNF through an amide bond. The designed immunosensors and aptasensors in this work were characterized using electrochemical impedance spectroscopy. The aptasensors, compared to the immunosensors gave better limit of detection values. The aptasensor outperforms the immunosensor in terms of its reusability and storability, while the immunosensor could not be regenerated for subsequent experiments. The potential applicability of all sensors in this work was also investigated, by detection of HER2 in spiked human serum with acceptable results.
- Full Text:
- Date Issued: 2022
Electrochemical detection of human epidermal growth factor receptor 2 using an aptamer on cobalt phthalocyanines–Cerium oxide nanoparticle conjugate
- Centane, Sixolile, Mgidlana, Sithi, Openda, Yolanda, Nyokong, Tebello
- Authors: Centane, Sixolile , Mgidlana, Sithi , Openda, Yolanda , Nyokong, Tebello
- Date: 2022
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/299835 , vital:57859 , xlink:href="https://doi.org/10.1016/j.bioelechem.2022.108146"
- Description: The role of the biointerface design towards the development of an impedimetric biosensor for the electrochemical detection of human epidermal growth factor receptor 2 (HER2) is investigated. Two novel cobalt phthalocyanines: cobalt tetraphenyl acetic acid phthalocyanine and cobalt tetraphenyl propionic acid phthalocyanine are compared as signal amplifiers and immobilization platforms of the HB5 aptamer towards the electrochemical detection of HER2. In addition, the phthalocyanines are coupled with the metal based cerium oxide nanoparticles. The efficiency of each electrode modification step and the performance of the constructed aptasensors were assessed by impedance spectroscopy. The aptasensors showed very low limit of detection values (all less than 0.2 ng/mL) with high sensitivity and stability. Furthermore, the aptasensors showed very good performance even in human serum samples. Considering these results, the aptasensors demonstrate great potential for improved monitoring of human epidermal growth factor receptor 2 levels for the management of breast cancers.
- Full Text:
- Date Issued: 2022
- Authors: Centane, Sixolile , Mgidlana, Sithi , Openda, Yolanda , Nyokong, Tebello
- Date: 2022
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/299835 , vital:57859 , xlink:href="https://doi.org/10.1016/j.bioelechem.2022.108146"
- Description: The role of the biointerface design towards the development of an impedimetric biosensor for the electrochemical detection of human epidermal growth factor receptor 2 (HER2) is investigated. Two novel cobalt phthalocyanines: cobalt tetraphenyl acetic acid phthalocyanine and cobalt tetraphenyl propionic acid phthalocyanine are compared as signal amplifiers and immobilization platforms of the HB5 aptamer towards the electrochemical detection of HER2. In addition, the phthalocyanines are coupled with the metal based cerium oxide nanoparticles. The efficiency of each electrode modification step and the performance of the constructed aptasensors were assessed by impedance spectroscopy. The aptasensors showed very low limit of detection values (all less than 0.2 ng/mL) with high sensitivity and stability. Furthermore, the aptasensors showed very good performance even in human serum samples. Considering these results, the aptasensors demonstrate great potential for improved monitoring of human epidermal growth factor receptor 2 levels for the management of breast cancers.
- Full Text:
- Date Issued: 2022
Impedimetric aptasensor for HER2 biomarker using graphene quantum dots, polypyrrole and cobalt phthalocyanine modified electrodes
- Centane, Sixolile, Nyokong, Tebello
- Authors: Centane, Sixolile , Nyokong, Tebello
- Date: 2022
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/230960 , vital:49836 , xlink:href="https://doi.org/10.1016/j.sbsr.2021.100467"
- Description: A method is presented for the electrochemical detection of the breast cancer biomarker human epidermal growth factor receptor 2 (HER2). A glassy carbon electrode was modified using two techniques known as sequential adsorption and electro-polymerization, and the results are compared. The highly conductive polypyrrole (PPy) is used, in the presence of sulfur/nitrogen doped graphene quantum dots (SNGQDs) and a known cobalt phthalocyanine (CoPc). The different nanomaterials were used as an immobilization platform for the HER2 specific HB5 aptamer via amide linkage. The nanomaterials were arranged in various ways on the glassy carbon electrode, to investigate the effect of the electrode interface on the operational characteristics of a biosensor. The immobilized aptamer selectively recognizes HER2 on the electrode interface, and this leads to an increased charge transfer resistance (Rct) of the electrode when using ferricyanide as the electrochemical probe. The developed immunosensors showed high sensitivity with the best detection limit of 0.00141 ng/mL. The results showed that the method is simple and sensitive enough for the determination of HER2 in serum samples with good reproducibility and accuracy.
- Full Text:
- Date Issued: 2022
- Authors: Centane, Sixolile , Nyokong, Tebello
- Date: 2022
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/230960 , vital:49836 , xlink:href="https://doi.org/10.1016/j.sbsr.2021.100467"
- Description: A method is presented for the electrochemical detection of the breast cancer biomarker human epidermal growth factor receptor 2 (HER2). A glassy carbon electrode was modified using two techniques known as sequential adsorption and electro-polymerization, and the results are compared. The highly conductive polypyrrole (PPy) is used, in the presence of sulfur/nitrogen doped graphene quantum dots (SNGQDs) and a known cobalt phthalocyanine (CoPc). The different nanomaterials were used as an immobilization platform for the HER2 specific HB5 aptamer via amide linkage. The nanomaterials were arranged in various ways on the glassy carbon electrode, to investigate the effect of the electrode interface on the operational characteristics of a biosensor. The immobilized aptamer selectively recognizes HER2 on the electrode interface, and this leads to an increased charge transfer resistance (Rct) of the electrode when using ferricyanide as the electrochemical probe. The developed immunosensors showed high sensitivity with the best detection limit of 0.00141 ng/mL. The results showed that the method is simple and sensitive enough for the determination of HER2 in serum samples with good reproducibility and accuracy.
- Full Text:
- Date Issued: 2022
Electrocatalytic Activity of Asymmetrical Cobalt Phthalocyanines in the Presence of N Doped Graphene Quantum Dots: The Push-pull Effects of Substituents
- Nkhahle, Reitumetse, Sekhosana, Kutloano E, Centane, Sixolile, Nyokong, Tebello
- Authors: Nkhahle, Reitumetse , Sekhosana, Kutloano E , Centane, Sixolile , Nyokong, Tebello
- Date: 2019
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/186904 , vital:44546 , xlink:href="https://doi.org/10.1002/elan.201800837"
- Description: A series of Co phthalocyanine (CoPc) derivatives and their respective nitrogen doped graphene quantum dot conjugates were used as catalysts towards the electrooxidation of hydrazine. Using a glassy carbon electrode as a support for the electrocatalysts, through cyclic voltammetry and chronoamperometry, the effects of combining the CoPcs with the nitrogen doped graphene quantum dots (NGQDs) were studied. The general observations made were that the NGQDs improve the catalytic activity of the CoPcs in both the p-p stacked and covalently linked conjugates by increasing the sensitivities and lowering the limits of detection with values as low as 0.43 mM being recorded.
- Full Text:
- Date Issued: 2019
- Authors: Nkhahle, Reitumetse , Sekhosana, Kutloano E , Centane, Sixolile , Nyokong, Tebello
- Date: 2019
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/186904 , vital:44546 , xlink:href="https://doi.org/10.1002/elan.201800837"
- Description: A series of Co phthalocyanine (CoPc) derivatives and their respective nitrogen doped graphene quantum dot conjugates were used as catalysts towards the electrooxidation of hydrazine. Using a glassy carbon electrode as a support for the electrocatalysts, through cyclic voltammetry and chronoamperometry, the effects of combining the CoPcs with the nitrogen doped graphene quantum dots (NGQDs) were studied. The general observations made were that the NGQDs improve the catalytic activity of the CoPcs in both the p-p stacked and covalently linked conjugates by increasing the sensitivities and lowering the limits of detection with values as low as 0.43 mM being recorded.
- Full Text:
- Date Issued: 2019
Electrocatalytic activity of a push-pull phthalocyanine in the presence of reduced and amino functionalized graphene quantum dots towards the electrooxidation of hydrazine
- Centane, Sixolile, Sekhosana, Kutloana E, Matshitse, Refilwe, Nyokong, Tebello
- Authors: Centane, Sixolile , Sekhosana, Kutloana E , Matshitse, Refilwe , Nyokong, Tebello
- Date: 2018
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/233456 , vital:50092 , xlink:href="https://doi.org/10.1016/j.jelechem.2018.05.005"
- Description: We report on the electrochemical behaviour of reduced graphene quantum dots (rGQDs) compared to amino functionalized graphene quantum dots (NH2GQDs). Reduction of the GQDs entails the elimination of the excessive carboxyl and hydrogen groups on the GQDs surface, thereby reducing the energy band gap. The energy band gap of graphene is directly proportional to the available oxygen atoms. The two GQD types were conjugated to a novel cobalt phthalocyanine (cobalt tris-(tert-butyl phenoxy)-mono-carboxyphenoxy phthalocyanine, CoPc) via covalent and nom-covalent interactions. The resulting conjugates were tested towards the electrooxidation of hydrazine. The conjugates are represented as rGQDs(π)CoPc, NH2(π)CoPc, rGQDs@CoPc and NH2GQDs@CoPc. The resulting conjugates were adsorbed onto a glassy carbon electrode using the drop and dry method. The lowest limit of detection (LOD) was obtained for rGQDs(π)CoPc.
- Full Text:
- Date Issued: 2018
- Authors: Centane, Sixolile , Sekhosana, Kutloana E , Matshitse, Refilwe , Nyokong, Tebello
- Date: 2018
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/233456 , vital:50092 , xlink:href="https://doi.org/10.1016/j.jelechem.2018.05.005"
- Description: We report on the electrochemical behaviour of reduced graphene quantum dots (rGQDs) compared to amino functionalized graphene quantum dots (NH2GQDs). Reduction of the GQDs entails the elimination of the excessive carboxyl and hydrogen groups on the GQDs surface, thereby reducing the energy band gap. The energy band gap of graphene is directly proportional to the available oxygen atoms. The two GQD types were conjugated to a novel cobalt phthalocyanine (cobalt tris-(tert-butyl phenoxy)-mono-carboxyphenoxy phthalocyanine, CoPc) via covalent and nom-covalent interactions. The resulting conjugates were tested towards the electrooxidation of hydrazine. The conjugates are represented as rGQDs(π)CoPc, NH2(π)CoPc, rGQDs@CoPc and NH2GQDs@CoPc. The resulting conjugates were adsorbed onto a glassy carbon electrode using the drop and dry method. The lowest limit of detection (LOD) was obtained for rGQDs(π)CoPc.
- Full Text:
- Date Issued: 2018
Effects of substituents on the electrocatalytic activity of cobalt phthalocyanines when conjugated to graphene quantum dots
- Centane, Sixolile, Achadu, Ojodomo John, Nyokong, Tebello
- Authors: Centane, Sixolile , Achadu, Ojodomo John , Nyokong, Tebello
- Date: 2017
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/188237 , vital:44737 , xlink:href="https://doi.org/10.1002/elan.201700252"
- Description: We report on the π–π interactions between graphene quantum dots (GQDs) and the following cobalt phthalocyanine derivatives: cobalt monocarboxyphenoxy phthalocyanine (complex 1), cobalt tetracarboxyphenoxyphthalocyanine (complex 2), and cobalt tetraaminophenoxy phthalocyanine (complex 3). The conjugates (conj) with GQDs are represented as 1@GQDs(conj), 2@GQDs(conj) and 3@GQDs(conj), respectively. The resulting phthalocyanine/GQDs conjugates were adsorbed on containing a glassy carbon electrode (GCE) using the drop and dry method. We explore the electrochemical properties of phthalocyanines functionalized with both electron withdrawing groups and electron donating groups when non-covalently linked to the π-electron rich graphene quantum dots. GCE/3, GCE/2@GQDs(conj) and GCE/1@GQDs(conj) had the lowest limits of detection (LOD). Sequentially modified electrodes showed less favourable detection limits compared to the conjugates.
- Full Text:
- Date Issued: 2017
- Authors: Centane, Sixolile , Achadu, Ojodomo John , Nyokong, Tebello
- Date: 2017
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/188237 , vital:44737 , xlink:href="https://doi.org/10.1002/elan.201700252"
- Description: We report on the π–π interactions between graphene quantum dots (GQDs) and the following cobalt phthalocyanine derivatives: cobalt monocarboxyphenoxy phthalocyanine (complex 1), cobalt tetracarboxyphenoxyphthalocyanine (complex 2), and cobalt tetraaminophenoxy phthalocyanine (complex 3). The conjugates (conj) with GQDs are represented as 1@GQDs(conj), 2@GQDs(conj) and 3@GQDs(conj), respectively. The resulting phthalocyanine/GQDs conjugates were adsorbed on containing a glassy carbon electrode (GCE) using the drop and dry method. We explore the electrochemical properties of phthalocyanines functionalized with both electron withdrawing groups and electron donating groups when non-covalently linked to the π-electron rich graphene quantum dots. GCE/3, GCE/2@GQDs(conj) and GCE/1@GQDs(conj) had the lowest limits of detection (LOD). Sequentially modified electrodes showed less favourable detection limits compared to the conjugates.
- Full Text:
- Date Issued: 2017
Nanocomposites of sulphur-nitrogen co-doped graphene oxide nanosheets and cobalt mono carboxyphenoxy phthalocyanines for facile electrocatalysis
- Shumba, Munyaradzi, Centane, Sixolile, Chindeka, Francis, Nyokong, Tebello
- Authors: Shumba, Munyaradzi , Centane, Sixolile , Chindeka, Francis , Nyokong, Tebello
- Date: 2017
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/239665 , vital:50753 , xlink:href="https://doi.org/10.1016/j.jelechem.2017.03.006"
- Description: Nanocomposites consisting of cobalt mono carboxyphenoxy phthalocyanine (CoMCPhPc) either covalently linked to graphene oxide nanosheets (GONS), sulphur doped graphene oxide nanosheets (SDGONS), nitrogen doped graphene oxide nanosheets (NDGONS) or sulphur/nitrogen co-doped graphene oxide nanosheets (SNDGONS) or sequentially added were used to modify glassy carbon electrode. The modified electrodes were characterised using several techniques: voltammetry, X-ray photon spectroscopy and scanning electron spectroscopy before testing their activity on the detection of hydrogen peroxide at pH 7. The presence of SNDGONS had a significant improvement on the currents as compared to CoMCPhPc modification alone in both sequentially added or covalently linked to MPcs. CoMCPhPc-SNDGONS(seq)-GCE and CoMCPhPc-SDGONS(linked)-GCE resulted in impressive limits of detection and catalytic rate constant values of 1.58 nM and 5.44 nM, 3.07 × 105 M−1 s−1 and 3.01 × 103 M−1 s−1 respectively. Gibbs energy value was determined to be −21.22 kJ mol−1 for CoMCPhPc-SNDGONS(linked)-GCE indicative of a facile spontaneous electroreduction reaction on the surface of this electrode.
- Full Text:
- Date Issued: 2017
- Authors: Shumba, Munyaradzi , Centane, Sixolile , Chindeka, Francis , Nyokong, Tebello
- Date: 2017
- Subjects: To be catalogued
- Language: English
- Type: text , article
- Identifier: http://hdl.handle.net/10962/239665 , vital:50753 , xlink:href="https://doi.org/10.1016/j.jelechem.2017.03.006"
- Description: Nanocomposites consisting of cobalt mono carboxyphenoxy phthalocyanine (CoMCPhPc) either covalently linked to graphene oxide nanosheets (GONS), sulphur doped graphene oxide nanosheets (SDGONS), nitrogen doped graphene oxide nanosheets (NDGONS) or sulphur/nitrogen co-doped graphene oxide nanosheets (SNDGONS) or sequentially added were used to modify glassy carbon electrode. The modified electrodes were characterised using several techniques: voltammetry, X-ray photon spectroscopy and scanning electron spectroscopy before testing their activity on the detection of hydrogen peroxide at pH 7. The presence of SNDGONS had a significant improvement on the currents as compared to CoMCPhPc modification alone in both sequentially added or covalently linked to MPcs. CoMCPhPc-SNDGONS(seq)-GCE and CoMCPhPc-SDGONS(linked)-GCE resulted in impressive limits of detection and catalytic rate constant values of 1.58 nM and 5.44 nM, 3.07 × 105 M−1 s−1 and 3.01 × 103 M−1 s−1 respectively. Gibbs energy value was determined to be −21.22 kJ mol−1 for CoMCPhPc-SNDGONS(linked)-GCE indicative of a facile spontaneous electroreduction reaction on the surface of this electrode.
- Full Text:
- Date Issued: 2017
- «
- ‹
- 1
- ›
- »