Systematic effects and mitigation strategies in observations of cosmic re-ionisation with the Hydrogen Epoch of Reionization Array
- Authors: Charles, Ntsikelelo
- Date: 2024
- Subjects: Uncatalogued
- Language: English
- Type: Academic theses , Doctoral theses , text
- Identifier: http://hdl.handle.net/10962/432605 , vital:72886
- Description: The 21 cm transition from neutral Hydrogen promises to be the best observational probe of the Epoch of Reionisation (EoR). It has driven the construction of the new generation of lowfrequency radio interferometric arrays, including the Hydrogen Epoch of Reionization Array (HERA). The main difficulty in measuring the 21 cm signal is the presence of bright foregrounds that require very accurate interferometric calibration. However, the non-smooth instrumental response of the antenna as a result of mutual coupling complicates the calibration process by introducing non-smooth calibration errors. Additionally, incomplete sky models are typically used in calibration due to the limited depth and resolution of current source catalogues. Combined with the instrumental response, the use of incomplete sky models during calibration can result in non-smooth calibration errors. These, overall, impart spectral structure on smooth foregrounds, leading to foreground power leakage into the EoR window. In this thesis we explored the use of fringe rate filters (Parsons et al., 2016) as a mean to mitigate calibration errors resulting from the effects of mutual coupling and the use of an incomplete sky model during calibration. We found that the use of a simple notch filter mitigates calibration errors reducing the foreground power leakage into the EoR window by a factor of ∼ 102. Thyagarajan et al. (2018) proposed the use of closure phase quantities as a means to detect the 21 cm signal, which has the advantage of being independent (to first order) from calibration errors and, therefore, bypasses the need for accurate calibration. In this thesis, we explore the impact of primary beam patterns affected by mutual coupling on the closure phase. We found that primary beams affected by mutual coupling lead to a leakage of foreground power into the EoR window, which can be up to ∼ 104 times and is mainly caused by the unsmooth spectral structure primary of primary beam sidelobes affected by mutual coupling. This power leakage was confined to k < 0.3 pseudo h Mpc−1. Lastly, we also proposed and demonstrated an analysis technique that can be used to derive a flux scale correction in post-calibrated HERA data. We found that after applying flux scale correction to calibrated HERA data, the bandpass error reduces significantly, with an improvement of 6%. The derived flux scale correction was antenna-independent, and it can be applied to fix the overall visibility spectrum scale of H4C data post-calibration in a fashion similar to Jacobs et al. (2013). , Thesis (PhD) -- Faculty of Science, Physics and Electronics, 2024
- Full Text:
- Date Issued: 2024
- Authors: Charles, Ntsikelelo
- Date: 2024
- Subjects: Uncatalogued
- Language: English
- Type: Academic theses , Doctoral theses , text
- Identifier: http://hdl.handle.net/10962/432605 , vital:72886
- Description: The 21 cm transition from neutral Hydrogen promises to be the best observational probe of the Epoch of Reionisation (EoR). It has driven the construction of the new generation of lowfrequency radio interferometric arrays, including the Hydrogen Epoch of Reionization Array (HERA). The main difficulty in measuring the 21 cm signal is the presence of bright foregrounds that require very accurate interferometric calibration. However, the non-smooth instrumental response of the antenna as a result of mutual coupling complicates the calibration process by introducing non-smooth calibration errors. Additionally, incomplete sky models are typically used in calibration due to the limited depth and resolution of current source catalogues. Combined with the instrumental response, the use of incomplete sky models during calibration can result in non-smooth calibration errors. These, overall, impart spectral structure on smooth foregrounds, leading to foreground power leakage into the EoR window. In this thesis we explored the use of fringe rate filters (Parsons et al., 2016) as a mean to mitigate calibration errors resulting from the effects of mutual coupling and the use of an incomplete sky model during calibration. We found that the use of a simple notch filter mitigates calibration errors reducing the foreground power leakage into the EoR window by a factor of ∼ 102. Thyagarajan et al. (2018) proposed the use of closure phase quantities as a means to detect the 21 cm signal, which has the advantage of being independent (to first order) from calibration errors and, therefore, bypasses the need for accurate calibration. In this thesis, we explore the impact of primary beam patterns affected by mutual coupling on the closure phase. We found that primary beams affected by mutual coupling lead to a leakage of foreground power into the EoR window, which can be up to ∼ 104 times and is mainly caused by the unsmooth spectral structure primary of primary beam sidelobes affected by mutual coupling. This power leakage was confined to k < 0.3 pseudo h Mpc−1. Lastly, we also proposed and demonstrated an analysis technique that can be used to derive a flux scale correction in post-calibrated HERA data. We found that after applying flux scale correction to calibrated HERA data, the bandpass error reduces significantly, with an improvement of 6%. The derived flux scale correction was antenna-independent, and it can be applied to fix the overall visibility spectrum scale of H4C data post-calibration in a fashion similar to Jacobs et al. (2013). , Thesis (PhD) -- Faculty of Science, Physics and Electronics, 2024
- Full Text:
- Date Issued: 2024
Discovery and classification of compact radio sources in the MeerKAT Galactic Centre data
- Authors: Rammala, Isabella Dineo
- Date: 2023-10-13
- Subjects: Uncatalogued
- Language: English
- Type: Academic theses , Doctoral theses , text
- Identifier: http://hdl.handle.net/10962/432218 , vital:72852
- Description: Access restricted. Expected release date in 2025. , Thesis (PhD) -- Faculty of Science, Physics and Electronics, 2023
- Full Text:
- Date Issued: 2023-10-13
- Authors: Rammala, Isabella Dineo
- Date: 2023-10-13
- Subjects: Uncatalogued
- Language: English
- Type: Academic theses , Doctoral theses , text
- Identifier: http://hdl.handle.net/10962/432218 , vital:72852
- Description: Access restricted. Expected release date in 2025. , Thesis (PhD) -- Faculty of Science, Physics and Electronics, 2023
- Full Text:
- Date Issued: 2023-10-13
A statistical study of travelling ionospheric disturbances over the African-European and American sectors
- Authors: Thaganyana, Golekamang Piet
- Date: 2023-03-31
- Subjects: Uncatalogued
- Language: English
- Type: Academic theses , Doctoral theses , text
- Identifier: http://hdl.handle.net/10962/422541 , vital:71956 , DOI 10.21504/10962/422543
- Description: This research presents a long-term statistical study of travelling ionospheric disturbances (TIDs) of low- and high-latitude origin over the American and African-European sectors between 2010 and 2018. The TIDs of low latitude origin (hereafter known as poleward TIDs) were studied in both quiet and disturbed conditions, whereas the equatorward TIDs were only studied during quiet conditions. The Kp > 4 and Dst_ -50 nT was used as a criterion for geomagnetic disturbed conditions, while the four geomagnetically quiet days were selected each month based on Kp < 3. Observations of TIDs are made using Global Navigational Satellite Systems (GNSS) total electron content derived data. During quiet conditions, seven and two transhemispheric TIDs were identified over the African-European and American sectors, respectively. The observed TIDs originated from the wintertime hemisphere and propagated into the summertime hemisphere. The horizontal velocity, periods, and horizontal wavelengths of TIDs are in range of cH = 120-274 m/s, 48-80 min and _H = 379-1104 km, respectively. These quiet-time equatorward TIDs have been associated with tertiary gravity waves (GWs) from the dissipation of secondary GWs which are in turn generated from the dissipation of mountain waves (MWs) as a result of excited orographic forcing. The poleward TIDs during geomagnetically quiet conditions over the African and American sectors occur mainly during local daytime. Poleward TIDs were observed mostly in the African-European sector than the American sector. Their horizontal propagation velocities and periods range between 129-280 m/s and 39-70 min over African-European and American sectors. Although the mechanisms responsible for launching quiet-time poleward TIDs have not been established in this study, lower atmospheric processes such as convection systems, sudden stratospheric warming and cold weather fronts may have a role in their generation. During geomagnetic storms in the African sector, almost all poleward TIDs (with the exception of two cases) during the main phase were large-scale with horizontal velocities and periods ranging from 250-503 m/s and 30 min to 2 hours. During recovery phase, poleward TIDs fall under the category of medium scale. In the American sector, the majority of poleward TIDs occurred during the storm's main phase, as opposed to the African-European sector, which experienced a significant number of poleward TIDs during the recovery phase. The periods and horizontal velocities of TIDs range from 45 min-1.5 h and 180-296 m/s during main phase. During the recovery phase, the horizontal velocity and period range from 177-271 m/s and 40-1.5 h, respectively. Overall, it has been shown that statistically, changes in equatorial electrodynamics related to enhanced eastward electric _eld and hence increased equatorial electrojet (vertical E_B drift) correlates highly with the reported poleward TIDs. , Thesis (PhD) -- Faculty of Science, Physics and Electronics, 2023
- Full Text:
- Date Issued: 2023-03-31
- Authors: Thaganyana, Golekamang Piet
- Date: 2023-03-31
- Subjects: Uncatalogued
- Language: English
- Type: Academic theses , Doctoral theses , text
- Identifier: http://hdl.handle.net/10962/422541 , vital:71956 , DOI 10.21504/10962/422543
- Description: This research presents a long-term statistical study of travelling ionospheric disturbances (TIDs) of low- and high-latitude origin over the American and African-European sectors between 2010 and 2018. The TIDs of low latitude origin (hereafter known as poleward TIDs) were studied in both quiet and disturbed conditions, whereas the equatorward TIDs were only studied during quiet conditions. The Kp > 4 and Dst_ -50 nT was used as a criterion for geomagnetic disturbed conditions, while the four geomagnetically quiet days were selected each month based on Kp < 3. Observations of TIDs are made using Global Navigational Satellite Systems (GNSS) total electron content derived data. During quiet conditions, seven and two transhemispheric TIDs were identified over the African-European and American sectors, respectively. The observed TIDs originated from the wintertime hemisphere and propagated into the summertime hemisphere. The horizontal velocity, periods, and horizontal wavelengths of TIDs are in range of cH = 120-274 m/s, 48-80 min and _H = 379-1104 km, respectively. These quiet-time equatorward TIDs have been associated with tertiary gravity waves (GWs) from the dissipation of secondary GWs which are in turn generated from the dissipation of mountain waves (MWs) as a result of excited orographic forcing. The poleward TIDs during geomagnetically quiet conditions over the African and American sectors occur mainly during local daytime. Poleward TIDs were observed mostly in the African-European sector than the American sector. Their horizontal propagation velocities and periods range between 129-280 m/s and 39-70 min over African-European and American sectors. Although the mechanisms responsible for launching quiet-time poleward TIDs have not been established in this study, lower atmospheric processes such as convection systems, sudden stratospheric warming and cold weather fronts may have a role in their generation. During geomagnetic storms in the African sector, almost all poleward TIDs (with the exception of two cases) during the main phase were large-scale with horizontal velocities and periods ranging from 250-503 m/s and 30 min to 2 hours. During recovery phase, poleward TIDs fall under the category of medium scale. In the American sector, the majority of poleward TIDs occurred during the storm's main phase, as opposed to the African-European sector, which experienced a significant number of poleward TIDs during the recovery phase. The periods and horizontal velocities of TIDs range from 45 min-1.5 h and 180-296 m/s during main phase. During the recovery phase, the horizontal velocity and period range from 177-271 m/s and 40-1.5 h, respectively. Overall, it has been shown that statistically, changes in equatorial electrodynamics related to enhanced eastward electric _eld and hence increased equatorial electrojet (vertical E_B drift) correlates highly with the reported poleward TIDs. , Thesis (PhD) -- Faculty of Science, Physics and Electronics, 2023
- Full Text:
- Date Issued: 2023-03-31
Dynamics of charge movement in ∞-Al2O3:C,Mg using thermoluminescence phototransferred and optically stimulated luminescence
- Authors: Lontsi Sob, Aaron Joel
- Date: 2022-04-08
- Subjects: Thermoluminescence , Optically stimulated luminescence , Phototransfer , Deep traps , Phototransferred thermoluminescence (PTTL)
- Language: English
- Type: Academic theses , Doctoral theses , text
- Identifier: http://hdl.handle.net/10962/294607 , vital:57237 , DOI 10.21504/10962/294607
- Description: The dosimetric features of ∞-Al2O3:C,Mg have been investigated for unannealed and annealed samples. The unannealed sample is referred to as sample A whereas the samples annealed at 700, 900 and 1200°C for 15 minutes each are referred to as samples B, C and D respectively. A glow curve of unannealed ∞-Al2O3:C,Mg measured at 1°C/s after irradiation to 2.0 Gy consists of peaks at 43, 73, 164, 195, 246, 284, 336 and 374°C respectively. For sample B (annealed at 700°C), a glow curve measured at 1°C/s after irradiation to 3.0 Gy has peaks at 46, 76, 100, 170, 199, 290, 330 and 375°C whereas the glow curve of sample C (annealed at 900°C) recorded under the same conditions consists of peaks at 49, 80, 100, 174, 206, 235, 290, 335 and 375°C respectively. Sample D (annealed at 1200°C) is the most sensitive of the four samples. A glow curve of sample D measured at 1°C/s after irradiation to 0.2 Gy has peaks at 52, 82, 102, 174, 234, 288 and 384°C respectively. The peaks are labelled I-VIII in order of appearance. The 100°C peak, labelled IIa, is induced by annealing at or above 700°C. The dose response of these peaks was studied for doses within 0.1-8.2 Gy. The reported peaks follow first-order kinetics irrespective of annealing temperature. Peaks I-III of each sample are reproduced under phototransfer for preheating up to 400°C. For the unannealed sample, the reproduced peaks are labelled A1-A3 whereas for the annealed samples, they are labelled B1-B3, C1-C3 and D1-D3 respectively. The annealing-induced peak at 100°C is reproduced as B2a, C2a and D2a for samples B, C and D respectively. A PTTL peak labelled C2b or D2b is also observed near 140°C in samples C and D. In addition to these PTTL peaks, a PTTL peak corresponding to peak IV is also found for sample D and for the unannealed sample. As the corresponding conventional peaks, the PTTL peaks of each sample follow first-order kinetics. Peak I and its corresponding PTTL peak for each sample are unstable and fade to a minimal level after 300 s of storage time. On the other hand, peak II of each sample and its corresponding PTTL peak could still be observed with delay up to 5000 s. Peak III of the unannealed sample remains stable with storage time up to 48 hours. Irrespective of annealing, the trap corresponding to peak III is the most sensitive to optical stimulation. Time-dependent profiles of PTTL from unannealed and annealed ∞-Al2O3:C,Mg were also studied. The mathematical analysis of the PTTL time-response profiles is based on experimental results. The role of various electron traps in PTTL was determined by using pulse annealing and by monitoring the dependence of peak intensity on duration of illumination for peaks not removed by preheating. The presence and role of deep traps were further demonstrated with thermally assisted optically stimulated luminescence. For the unannealed sample, the activation energy for thermal assistance is 0.033 ± 0.001 eV and the activation energy for thermal i quenching is 1.043 ± 0.001 eV. For sample C, the activation energy for thermal assistance is 0.044 ± 0.003 eV whereas that for thermal quenching is 1.110 ± 0.006 eV. The values for the activation energy for thermal assistance are lower than those reported in literature. Only the values for the activation energy for thermal quenching are somewhat comparable to values reported elsewhere. , Thesis (PhD) -- Faculty of Science, Physics and Electronics, 2022
- Full Text:
- Date Issued: 2022-04-08
- Authors: Lontsi Sob, Aaron Joel
- Date: 2022-04-08
- Subjects: Thermoluminescence , Optically stimulated luminescence , Phototransfer , Deep traps , Phototransferred thermoluminescence (PTTL)
- Language: English
- Type: Academic theses , Doctoral theses , text
- Identifier: http://hdl.handle.net/10962/294607 , vital:57237 , DOI 10.21504/10962/294607
- Description: The dosimetric features of ∞-Al2O3:C,Mg have been investigated for unannealed and annealed samples. The unannealed sample is referred to as sample A whereas the samples annealed at 700, 900 and 1200°C for 15 minutes each are referred to as samples B, C and D respectively. A glow curve of unannealed ∞-Al2O3:C,Mg measured at 1°C/s after irradiation to 2.0 Gy consists of peaks at 43, 73, 164, 195, 246, 284, 336 and 374°C respectively. For sample B (annealed at 700°C), a glow curve measured at 1°C/s after irradiation to 3.0 Gy has peaks at 46, 76, 100, 170, 199, 290, 330 and 375°C whereas the glow curve of sample C (annealed at 900°C) recorded under the same conditions consists of peaks at 49, 80, 100, 174, 206, 235, 290, 335 and 375°C respectively. Sample D (annealed at 1200°C) is the most sensitive of the four samples. A glow curve of sample D measured at 1°C/s after irradiation to 0.2 Gy has peaks at 52, 82, 102, 174, 234, 288 and 384°C respectively. The peaks are labelled I-VIII in order of appearance. The 100°C peak, labelled IIa, is induced by annealing at or above 700°C. The dose response of these peaks was studied for doses within 0.1-8.2 Gy. The reported peaks follow first-order kinetics irrespective of annealing temperature. Peaks I-III of each sample are reproduced under phototransfer for preheating up to 400°C. For the unannealed sample, the reproduced peaks are labelled A1-A3 whereas for the annealed samples, they are labelled B1-B3, C1-C3 and D1-D3 respectively. The annealing-induced peak at 100°C is reproduced as B2a, C2a and D2a for samples B, C and D respectively. A PTTL peak labelled C2b or D2b is also observed near 140°C in samples C and D. In addition to these PTTL peaks, a PTTL peak corresponding to peak IV is also found for sample D and for the unannealed sample. As the corresponding conventional peaks, the PTTL peaks of each sample follow first-order kinetics. Peak I and its corresponding PTTL peak for each sample are unstable and fade to a minimal level after 300 s of storage time. On the other hand, peak II of each sample and its corresponding PTTL peak could still be observed with delay up to 5000 s. Peak III of the unannealed sample remains stable with storage time up to 48 hours. Irrespective of annealing, the trap corresponding to peak III is the most sensitive to optical stimulation. Time-dependent profiles of PTTL from unannealed and annealed ∞-Al2O3:C,Mg were also studied. The mathematical analysis of the PTTL time-response profiles is based on experimental results. The role of various electron traps in PTTL was determined by using pulse annealing and by monitoring the dependence of peak intensity on duration of illumination for peaks not removed by preheating. The presence and role of deep traps were further demonstrated with thermally assisted optically stimulated luminescence. For the unannealed sample, the activation energy for thermal assistance is 0.033 ± 0.001 eV and the activation energy for thermal i quenching is 1.043 ± 0.001 eV. For sample C, the activation energy for thermal assistance is 0.044 ± 0.003 eV whereas that for thermal quenching is 1.110 ± 0.006 eV. The values for the activation energy for thermal assistance are lower than those reported in literature. Only the values for the activation energy for thermal quenching are somewhat comparable to values reported elsewhere. , Thesis (PhD) -- Faculty of Science, Physics and Electronics, 2022
- Full Text:
- Date Issued: 2022-04-08
Neutral Atomic Hydrogen in Gravitationally Lensed Systems
- Authors: Blecher, Tariq Dylan
- Date: 2021-10-29
- Subjects: Uncatalogued
- Language: English
- Type: Doctoral theses , text
- Identifier: http://hdl.handle.net/10962/192776 , vital:45263
- Description: Thesis (PhD) -- Faculty of Law, Law, 2021
- Full Text:
- Date Issued: 2021-10-29
- Authors: Blecher, Tariq Dylan
- Date: 2021-10-29
- Subjects: Uncatalogued
- Language: English
- Type: Doctoral theses , text
- Identifier: http://hdl.handle.net/10962/192776 , vital:45263
- Description: Thesis (PhD) -- Faculty of Law, Law, 2021
- Full Text:
- Date Issued: 2021-10-29
On the gravitational dual to strongly coupled fluids
- Authors: Shawa, Mark Musonda Webster
- Date: 2021-10-29
- Subjects: Quantum gravity , String models , Gauge fields (Physics) , Scattering amplitude (Nuclear physics) , Quark-gluon plasma , Anti-de Sitter/Conformal Field Theory (AdS/CFT) , Gauge/gravity duality
- Language: English
- Type: Doctoral theses , text
- Identifier: http://hdl.handle.net/10962/192933 , vital:45280 , 10.21504/10962/192933
- Description: This thesis discusses the prospect of finding the gravitational dual to the strongly coupled conformal fluids, with a special interest in the quark-gluon plasma. Such a task can be achieved by matching certain physical observables of two apparently different theories that are dually related owing to the fact that the same string theory can be viewed in two different ways. This is particularly useful when one of the theories is intractable while its dual is manageable. We begin by postulating a particular type of gravitational theory from which we determine graviton scattering amplitudes in a special regime of high momentum. Using the gauge–gravity duality dictionary, the graviton scattering amplitudes can be mapped to stress-tensor correlation functions in the gauge theory. One of the outcomes of high-energy scattering experiments involving the quark-gluon plasma is stress-tensor correlator data. This thesis provides an algorithm for matching graviton scattering amplitudes with stress-tensor correlator data which, in principle, can be used to identify the gravitational dual to the quark-gluon plasma. , Thesis (PhD) -- Faculty of Science, Physics and Electronics, 2021
- Full Text:
- Date Issued: 2021-10-29
- Authors: Shawa, Mark Musonda Webster
- Date: 2021-10-29
- Subjects: Quantum gravity , String models , Gauge fields (Physics) , Scattering amplitude (Nuclear physics) , Quark-gluon plasma , Anti-de Sitter/Conformal Field Theory (AdS/CFT) , Gauge/gravity duality
- Language: English
- Type: Doctoral theses , text
- Identifier: http://hdl.handle.net/10962/192933 , vital:45280 , 10.21504/10962/192933
- Description: This thesis discusses the prospect of finding the gravitational dual to the strongly coupled conformal fluids, with a special interest in the quark-gluon plasma. Such a task can be achieved by matching certain physical observables of two apparently different theories that are dually related owing to the fact that the same string theory can be viewed in two different ways. This is particularly useful when one of the theories is intractable while its dual is manageable. We begin by postulating a particular type of gravitational theory from which we determine graviton scattering amplitudes in a special regime of high momentum. Using the gauge–gravity duality dictionary, the graviton scattering amplitudes can be mapped to stress-tensor correlation functions in the gauge theory. One of the outcomes of high-energy scattering experiments involving the quark-gluon plasma is stress-tensor correlator data. This thesis provides an algorithm for matching graviton scattering amplitudes with stress-tensor correlator data which, in principle, can be used to identify the gravitational dual to the quark-gluon plasma. , Thesis (PhD) -- Faculty of Science, Physics and Electronics, 2021
- Full Text:
- Date Issued: 2021-10-29
- «
- ‹
- 1
- ›
- »