The human skin blanching assay for in vivo topical corticosteroid assessment. II. Subject- and observer-dependent variation in blanching responses
- Haigh, John M, Meyer, Eric, Smith, Eric W, Kanfer, Isadore
- Authors: Haigh, John M , Meyer, Eric , Smith, Eric W , Kanfer, Isadore
- Date: 1997
- Language: English
- Type: text , Article
- Identifier: vital:6382 , http://hdl.handle.net/10962/d1006300
- Description: The human skin blanching (vasoconstriction) assay for the assessment of topical corticosteroids has been in use for over 30 years, the intensity of the drug-induced blanching being assessed subjectively by eye. Both arms of several male and female volunteers are used for product application and more than one observer is used to estimate the degree of induced blanching. There are, therefore, numerous variables which are inherent in the assay procedure. This investigation consisted of three identical trials performed at 8-week intervals, utilising the same 18 volunteers and the same three observers in an attempt to address the question of reproducibility of the assay. From the results obtained it is clear that the assay methodology is capable of consistently distinguishing, on a rank order basis, between preparations which show similar blanching (chemically-equivalent formulations). The similarity of the results for the three individual trials gives considerable confidence to results produced using this methodology. An experiment designed to test the reproducibility of the blanching scores showed that the observers are capable of producing identical results even though visual observation is highly subjective.
- Full Text:
- Date Issued: 1997
- Authors: Haigh, John M , Meyer, Eric , Smith, Eric W , Kanfer, Isadore
- Date: 1997
- Language: English
- Type: text , Article
- Identifier: vital:6382 , http://hdl.handle.net/10962/d1006300
- Description: The human skin blanching (vasoconstriction) assay for the assessment of topical corticosteroids has been in use for over 30 years, the intensity of the drug-induced blanching being assessed subjectively by eye. Both arms of several male and female volunteers are used for product application and more than one observer is used to estimate the degree of induced blanching. There are, therefore, numerous variables which are inherent in the assay procedure. This investigation consisted of three identical trials performed at 8-week intervals, utilising the same 18 volunteers and the same three observers in an attempt to address the question of reproducibility of the assay. From the results obtained it is clear that the assay methodology is capable of consistently distinguishing, on a rank order basis, between preparations which show similar blanching (chemically-equivalent formulations). The similarity of the results for the three individual trials gives considerable confidence to results produced using this methodology. An experiment designed to test the reproducibility of the blanching scores showed that the observers are capable of producing identical results even though visual observation is highly subjective.
- Full Text:
- Date Issued: 1997
A capillary zone electrophoresis (CZE) method for the determination of cyclizine hydrochloride in tablets and suppositories
- Mohammadi, I, Kanfer, Isadore, Walker, Roderick B
- Authors: Mohammadi, I , Kanfer, Isadore , Walker, Roderick B
- Date: 2004
- Language: English
- Type: Article
- Identifier: vital:6406 , http://hdl.handle.net/10962/d1006479
- Description: Current compendial methods of assay for the analysis of cyclizine tablets involve the use of UV spectrophotometry. Since this is a non-selective technique its application to more complex dosage forms, such as suppositories, is unlikely to be appropriate. There is therefore a need for the development of a highly specific quantitative analytical method, such as high performance liquid chromatography (HPLC) or capillary electrophoresis (CE). The latter technique was chosen in view of some specific advantages over HPLC, such as the use of relatively non-toxic aqueous buffers, as opposed to organic solvents, which obviates the use of expensive HPLC grade solvents making CE more cost effective. Cyclizine was analyzed in 50 mM phosphate buffer (pH 2.3) and run at an applied voltage 25 kV. Detection sensitivity was enhanced by using a wavelength of 200 nm and samples were loaded hydrodynamically onto an uncoated fused-silica capillary (60 cm×50 mm i.d.). Chlorcyclizine was used as the internal standard and resolution of both compounds was achieved in less than 7 min. Stress testing was undertaken in order to investigate the appearance of breakdown products. The method has the requisite accuracy, selectivity, sensitivity and precision to assay cyclizine in tablets and suppositories. Degradation products resulting from the stress studies did not interfere with the detection of cyclizine and the assay is thus stability-indicating.
- Full Text:
- Date Issued: 2004
- Authors: Mohammadi, I , Kanfer, Isadore , Walker, Roderick B
- Date: 2004
- Language: English
- Type: Article
- Identifier: vital:6406 , http://hdl.handle.net/10962/d1006479
- Description: Current compendial methods of assay for the analysis of cyclizine tablets involve the use of UV spectrophotometry. Since this is a non-selective technique its application to more complex dosage forms, such as suppositories, is unlikely to be appropriate. There is therefore a need for the development of a highly specific quantitative analytical method, such as high performance liquid chromatography (HPLC) or capillary electrophoresis (CE). The latter technique was chosen in view of some specific advantages over HPLC, such as the use of relatively non-toxic aqueous buffers, as opposed to organic solvents, which obviates the use of expensive HPLC grade solvents making CE more cost effective. Cyclizine was analyzed in 50 mM phosphate buffer (pH 2.3) and run at an applied voltage 25 kV. Detection sensitivity was enhanced by using a wavelength of 200 nm and samples were loaded hydrodynamically onto an uncoated fused-silica capillary (60 cm×50 mm i.d.). Chlorcyclizine was used as the internal standard and resolution of both compounds was achieved in less than 7 min. Stress testing was undertaken in order to investigate the appearance of breakdown products. The method has the requisite accuracy, selectivity, sensitivity and precision to assay cyclizine in tablets and suppositories. Degradation products resulting from the stress studies did not interfere with the detection of cyclizine and the assay is thus stability-indicating.
- Full Text:
- Date Issued: 2004
Generic substitution: the use of medicinal products containing different salts and implications for safety and efficacy
- Verbeeck, R K, Kanfer, Isadore, Walker, Roderick B
- Authors: Verbeeck, R K , Kanfer, Isadore , Walker, Roderick B
- Date: 2006
- Language: English
- Type: text , Article
- Identifier: vital:6445 , http://hdl.handle.net/10962/d1006632
- Description: In their quest to gain early entry of new generic products into the market prior to patent expiration, one of the strategies pursued by generic drug product manufacturers is to incorporate different salts of an approved active pharmaceutical ingredient (API) in a brand company's marketed dosage form and subject such dosage forms to bioequivalence assessment. These initiatives present challenges to regulatory authorities where the decision to approve bioequivalent products containing such pharmaceutical alternatives must be considered in the light of safety and efficacy, and more particularly, with respect to their substitutability. This article describes the various issues and contentions associated with the concept of pharmaceutical alternatives, specifically with respect to the uses of different salts and the implications for safety, efficacy and generic substitution.
- Full Text:
- Date Issued: 2006
- Authors: Verbeeck, R K , Kanfer, Isadore , Walker, Roderick B
- Date: 2006
- Language: English
- Type: text , Article
- Identifier: vital:6445 , http://hdl.handle.net/10962/d1006632
- Description: In their quest to gain early entry of new generic products into the market prior to patent expiration, one of the strategies pursued by generic drug product manufacturers is to incorporate different salts of an approved active pharmaceutical ingredient (API) in a brand company's marketed dosage form and subject such dosage forms to bioequivalence assessment. These initiatives present challenges to regulatory authorities where the decision to approve bioequivalent products containing such pharmaceutical alternatives must be considered in the light of safety and efficacy, and more particularly, with respect to their substitutability. This article describes the various issues and contentions associated with the concept of pharmaceutical alternatives, specifically with respect to the uses of different salts and the implications for safety, efficacy and generic substitution.
- Full Text:
- Date Issued: 2006
- «
- ‹
- 1
- ›
- »